RA2 Retractable Extraction Arm

Designed specifically to extract welding fumes and dust from confined spaces, Diversitech’s RA2 Series Retractable Telescopic Capture Arm is perfect for small workstations and welding school booths. Capturing contaminants at source, the Telescopic Extraction Arm keeps you OSHA compliant while ensuring safe working environments for students and operators.

Completely self-supporting, the Retractable Telescopic Capture Arm provides operators with a durable and flexible solution for many industrial applications. Featuring an internal tubular structure, the arm easily extends and retracts as needed. The internally articulated arm with an extendable support structure and rotating swivel base provide exact positioning. Its flanged suction hood with handle guarantee a higher face velocity where more contaminants are captured at source.

Recommended Applications

  • Ideal for welding.
  • Ideal for soldering.
  • Ideal for VOC.
  • Not Ideal for thermal spray.
  • Not ideal for oil mist
  • Not ideal for painting

Overview

Designed specifically to extract welding fumes and dust from confined spaces, Diversitech’s RA2 Series Retractable Telescopic Capture Arm is perfect for small workstations and welding school booths. Capturing contaminants at source, the Telescopic Extraction Arm keeps you OSHA compliant while ensuring safe working environments for students and operators.

Completely self-supporting, the Retractable Telescopic Capture Arm provides operators with a durable and flexible solution for many industrial applications. Featuring an internal tubular structure, the arm easily extends and retracts as needed. The internally articulated arm with an extendable support structure and rotating swivel base provide exact positioning. Its flanged suction hood with handle guarantee a higher face velocity where more contaminants are captured at source.

Retractable Telescopic Capture Arms can be paired with wall-mounted fume extractors including the FRED Eco series, or bolted directly onto Diversitech’s Exhaust Blowers.

Benefits

  • Flexible and self-supporting
  • Capture-at-source for cleaner air
  • Compliant with OSHA guidelines for controlling weld fumes

Features

  • Wall or Post Mountable
  • Rotating Swivel Base
  • Lightweight Aluminum Construction

Options

  • Custom arm ranges available upon request

Models and Options

Technical Specifications

Model Product Dimensions (in.)
Width Height Length
RA-6H063 12 13.5 56

Learn how to get the most out of your RA2 Retractable Extraction Arm and troubleshoot common problems.
See our help topics and support videos below, and download the RA2 Retractable Extraction Arm product guide and owner’s manual.

How to..

+ Set up your RA2 Retractable Extraction Arm for the first time

 

Unpack Unit

  1. Inspect carton for any possible damage during transit and remove packing material.
  2. Remove packing material.
  3. Do not tip or invert while handling.
  4. You’ll find the item serial number, model and electrical ratings located on the nameplate. Write down information on the provided Maintenance Record found in the owner’s manual.

Installation

  1. Tools required:
    • 7/16 Socket or Wrench
    • 9/16 Socket or Wrench
    • Torque Wrench

Arm to Remote Mount Bracket Installation

  1. Unpack capture arm, hood, and base
  2. Wall mount bracket standard assembly:
    • Mount Swivel Base to Remote Mount Bracket.
    • Tighten all Bolts (8) with Washers (8).
    • Torque each bolt to 23 N m.
  3. Attach swivel base to remote mount bracket.
  4. Attach capture arm to swivel base:
    • Mount Swivel Base to Remote Mount Bracket.
    • Tighten all Bolts (8) with Washers (8).
    • Torque each bolt to 23 N m.
+ Perform Routine Maintenance

Yearly Inspection:

  1. Clean unreadable labels and exterior surfaces.
  2. Check for tears in flex hoses and fitting of hose clamp.

Troubleshooting

+ The suction arm is not able to support itself, the handling and positioning of the hood is compromised
  1. Check bolts to see if they’re loose. If so, tighten bolts gradually. Be careful not to overtighten.
+ The pipes break in the proximity of the junction
  1. The bolts of the clutches are tightened too much, to the point of overcoming the resistance of the junctions. Loosen the bolts of the clutches and replace the pipes:
    • The forearm tube of connection hood. (Replacement can be done by customer.)
    • The part of the pipe where there’s a spring. (Replacement must be done by manufacturer for safety reasons.)
+ Broken hose clamps
  1. There was wear, drilling and/ or abrasion caused by incandescent material extracted by the arm. Remove and replace hose clamps.
+ The fan’s suction arm stops suddenly
  1. There may be a block of electric current. Reactivate the power source of the current.
  2. Check the fuse to see if it’s blown. Replace if necessary.
  3. Check the thermal switch to see if it has tripped. Open the control panel and reset the switch. Investigate the reason for the thermal cutoff.
  4. The engine may have blown. Repair or replace if possible. Refer to appropriate manual.

Guides