SPH 800

The SPH 800 Fume Extractor is designed for use in heavy-duty laser cutting and soldering applications. With nominal airflow capabilities up to 480 CFM, the SPH 800 series can easily be implemented at a standalone workstation or as a multi-station laser fume extractor depending on your capacity needs. Featuring a multi-stage filtration system with a variety of filter sequence configurations to address your fume extraction needs, an iSeries (digital) control panel and heavy-duty lockable casters for portability, the SPH 800 provides everything you need in a laser fume extractor.

Overview

The SPH 800 Fume Extractor is designed for use in heavy-duty laser cutting and soldering applications. With nominal airflow capabilities up to 480 CFM, the SPH 800 series can easily be implemented at a standalone workstation or as a multi-station laser fume extractor depending on your capacity needs. Featuring a multi-stage filtration system with a variety of filter sequence configurations to address your fume extraction needs, an iSeries (digital) control panel and heavy-duty lockable casters for portability, the SPH 800 provides everything you need in a laser fume extractor.

Benefits

The SPH 800 series features many benefits over competing portable fume extractors, including:

  • Portable plug and play design
  • Ultra-small footprint
  • Whisper quiet operation
  • CE and CSA-certified, RoHS compliant

Features

Each SPH 800 unit comes standard with the following features:

  • iSeries (digital) control panel
  • Multi-stage filtration system with HEPA
  • LaserBlue gel seal guarantees zero filter bypass
  • 6 ft hose included
  • Universal cable included – E427

Options

Need a customized solution? SPH 800 is available with many options suited to unique applications, including:

  • Three (3) Infinity or Dual Brushless motors
  • 3″ or 4″ diameter inlet / hose
  • Multiple filter sequence configurations (see Technical Specifications)
  • Knockout pad – F166

Models and Options

Technical Specifications

Product Number Motor Pressure CFM Volts/Phase/Hz Amps Shipping Weight Width Height Depth Noise(dB) Filter Sequence Filter Efficiency
1-0036-0701
(6 ft of 3″ HD hose/Dual 3″ inlets)
Infinity (3x) 90″ WC 360 230/1/50-60 12 150lbs
(68kg)
16″ 30″ 25.5″ 54dB(A) •Knockout Pad F166 (2x)
•2″ Pleated Dust Filter F071 (2x)
•2” HEPA Filter F074 (2x)
•8” Carbon Filter AG097 (2x)
•MERV 6-8
•MERV 10
•MERV 17
•N/A
1-0036-0711
(6 ft of 4″ HD hose/Dual 4″ inlets)
Infinity (3x) 90″ WC 360 230/1/50-60 12 150lbs
(68kg)
16″ 30″ 25.5″ 54dB(A) •Knockout Pad F166 (2x)
•2″ Pleated Dust Filter F071 (2x)
•2” HEPA Filter F074 (2x)
•8” Carbon Filter AG097 (2x)
•MERV 6-8
•MERV 10
•MERV 17
•N/A
1-0036-0702
(6 ft of 3″ HD hose/Dual 3″ inlets)
Infinity (3x) 90″ WC 360 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166
• 12″ Carbon Filter AG098
• MERV 6-8
• N/A
1-0036-0712
(6 ft of 4″ HD hose/Dual 4″ inlets)
Infinity (3x) 90″ WC 360 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166
• 12″ Carbon Filter AG098
• MERV 6-8
• N/A
1-0036-1701
(6 ft of 3″ HD hose/Dual 3″ inlets)
Dual Brushless 36″ WC 480 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166 (2x)
• 2″ Pleated Dust Filter F071 (2x)
• 2” HEPA Filter F074 (2x)
• 8” Carbon Filter AG097 (2x)
• MERV 6-8
• MERV 10
• MERV 17
• N/A
1-0036-1711
(6 ft of 4″ HD hose/Dual 4″ inlets)
Dual Brushless 36″ WC 480 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166 (2x)
• 2″ Pleated Dust Filter F071 (2x)
• 2” HEPA Filter F074 (2x)
• 8” Carbon Filter AG097 (2x)
• MERV 6-8
• MERV 10
• MERV 17
• N/A
1-0036-1702
(6 ft of 3″ HD hose/Dual 3″ inlets)
Dual Brushless 36″ WC 480 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166
• 12″ Carbon Filter AG098
• MERV 6-8
• N/A
1-0036-1712
(6 ft of 4″ HD hose/Dual 4″ inlets)
Dual Brushless 36″ WC 480 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166
• 12″ Carbon Filter AG098
• MERV 6-8
• N/A
1-0036-4701
(6 ft of 3″ HD hose/Dual 3″ inlets)
Dual Brushless 54″ WC 440 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166 (2x)
• 2″ Pleated Dust Filter F071 (2x)
• 2” HEPA Filter F074 (2x)
• 8” Carbon Filter AG097 (2x)
• MERV 6-8
• MERV 10
• MERV 17
• N/A
1-0036-4711
(6 ft of 4″ HD hose/Dual 4″ inlets)
Dual Brushless 54″ WC 440 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166 (2x)
• 2″ Pleated Dust Filter F071 (2x)
• 2” HEPA Filter F074 (2x)
• 8” Carbon Filter AG097 (2x)
• MERV 6-8
• MERV 10
• MERV 17
• N/A
1-0036-4702
(6 ft of 3″ HD hose/Dual 3″ inlets)
Dual Brushless 54″ WC 440 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166
• 12″ Carbon Filter AG098
• MERV 6-8
• N/A
1-0036-4712
(6 ft of 4″ HD hose/Dual 4″ inlets)
Dual Brushless 54″ WC 440 230/1/50-60 12 150 lbs
(68 kg)
16″ 30″ 25.5″ 54dB(A) • Knockout Pad F166
• 12″ Carbon Filter AG098
• MERV 6-8
• N/A

Learn how to get the most out of your Quatro Air unit and troubleshoot common problems. You can also download the owner’s manual for this unit for technical details and instructions.

How to..

+ Set Up Your Unit For The First Time

 

Introduction

Congratulations! You are now owner of a Quatro Air SPH 800 Fume Extractor, an advanced effective indoor dust and fume collection system
designed specifically to remove particulate matter and odour causing gas phase contaminants at the source. You can expect
a noticeable improvement in air quality as the SPH 800 system begins the process of reducing microscopic airborne
particulate.

Safety Precaution

Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which filters are installed &
replaced. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong
adapters to defeat proper grounding. If servicing the unit, be careful not to touch the motor as soon as it has been turned off. It is hot and can cause injury.

IMPORTANT: Ensure power supply is unplugged during maintenance or filter service

Pre Start-Up Checklist

  1. Upon arrival, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
  2. All filters are present and are correctly installed prior use
  3. Labels and serial numbers are present for future identification
  4. Verify that power supply is compatible with equipment. Check the unit is plugged into a grounded receptacle
  5. The casters (wheels) must be secure in place prior the moving the unit

Start-Up

WARNING: Do not operate unit until you’ve confirmed all filters have been installed

  1. Place the unit in the desired area for use. Ensure all filters are installed (remove all plastic wrapping)
  2. Make sure the air intake area (bottom) is not obstructed in any way
  3. Insert male end of power cord into grounded circuit
  4. Press RED POWER BUTTON, unit will start, press “+” or “-“ to switch speed “HIGHER” or “LOWER”
  5. Unit should now be functioning and operational
+ When To Replace Your Filters

Your unit comes equipped with a Service Filters light on the control panel. When this light is illuminated, it is recommened that you order new filters as soon as possible.
Reduced air flow is a common symptom of dirty filters.

+ My Motor Shuts Off

There are a couple of reasons why your motor may randomly turn off:

  • Possible Cause: Motor overheated, tripped on thermal cutout
  • Suggested Solution: Switch power off, unplug, wait till motor cools, replace filters/verify blockage.
  • Possible Cause: Motor/motor brushes past service life
  • Suggested Solution: Replace motor/motor brushes.