The SPH 800 Fume Extractor is designed for use in heavy-duty laser cutting and soldering applications. With nominal airflow capabilities up to 480 CFM, the SPH 800 series can easily be implemented at a standalone workstation or as a multi-station laser fume extractor depending on your capacity needs. Featuring a multi-stage filtration system with a variety of filter sequence configurations to address your fume extraction needs, an iSeries (digital) control panel and heavy-duty lockable casters for portability, the SPH 800 provides everything you need in a laser fume extractor.
The SPH 800 Fume Extractor is designed for use in heavy-duty laser cutting and soldering applications. With nominal airflow capabilities up to 480 CFM, the SPH 800 series can easily be implemented at a standalone workstation or as a multi-station laser fume extractor depending on your capacity needs. Featuring a multi-stage filtration system with a variety of filter sequence configurations to address your fume extraction needs, an iSeries (digital) control panel and heavy-duty lockable casters for portability, the SPH 800 provides everything you need in a laser fume extractor.
The SPH 800 series features many benefits over competing portable fume extractors, including:
Each SPH 800 unit comes standard with the following features:
Need a customized solution? SPH 800 is available with many options suited to unique applications, including:
Product Number | Motor | Pressure | CFM | Volts/Phase/Hz | Amps | Shipping Weight | Width | Height | Depth | Noise(dB) | Filter Sequence | Filter Efficiency |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1-0036-0701 (6 ft of 3″ HD hose/Dual 3″ inlets) |
Infinity (3x) | 90″ WC | 360 | 230/1/50-60 | 12 | 150lbs (68kg) |
16″ | 30″ | 25.5″ | 54dB(A) | •Knockout Pad F166 (2x) •2″ Pleated Dust Filter F071 (2x) •2” HEPA Filter F074 (2x) •8” Carbon Filter AG097 (2x) |
•MERV 6-8 •MERV 10 •MERV 17 •N/A |
1-0036-0711 (6 ft of 4″ HD hose/Dual 4″ inlets) |
Infinity (3x) | 90″ WC | 360 | 230/1/50-60 | 12 | 150lbs (68kg) |
16″ | 30″ | 25.5″ | 54dB(A) | •Knockout Pad F166 (2x) •2″ Pleated Dust Filter F071 (2x) •2” HEPA Filter F074 (2x) •8” Carbon Filter AG097 (2x) |
•MERV 6-8 •MERV 10 •MERV 17 •N/A |
1-0036-0702 (6 ft of 3″ HD hose/Dual 3″ inlets) |
Infinity (3x) | 90″ WC | 360 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 • 12″ Carbon Filter AG098 |
• MERV 6-8 • N/A |
1-0036-0712 (6 ft of 4″ HD hose/Dual 4″ inlets) |
Infinity (3x) | 90″ WC | 360 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 • 12″ Carbon Filter AG098 |
• MERV 6-8 • N/A |
1-0036-1701 (6 ft of 3″ HD hose/Dual 3″ inlets) |
Dual Brushless | 36″ WC | 480 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 (2x) • 2″ Pleated Dust Filter F071 (2x) • 2” HEPA Filter F074 (2x) • 8” Carbon Filter AG097 (2x) |
• MERV 6-8 • MERV 10 • MERV 17 • N/A |
1-0036-1711 (6 ft of 4″ HD hose/Dual 4″ inlets) |
Dual Brushless | 36″ WC | 480 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 (2x) • 2″ Pleated Dust Filter F071 (2x) • 2” HEPA Filter F074 (2x) • 8” Carbon Filter AG097 (2x) |
• MERV 6-8 • MERV 10 • MERV 17 • N/A |
1-0036-1702 (6 ft of 3″ HD hose/Dual 3″ inlets) |
Dual Brushless | 36″ WC | 480 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 • 12″ Carbon Filter AG098 |
• MERV 6-8 • N/A |
1-0036-1712 (6 ft of 4″ HD hose/Dual 4″ inlets) |
Dual Brushless | 36″ WC | 480 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 • 12″ Carbon Filter AG098 |
• MERV 6-8 • N/A |
1-0036-4701 (6 ft of 3″ HD hose/Dual 3″ inlets) |
Dual Brushless | 54″ WC | 440 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 (2x) • 2″ Pleated Dust Filter F071 (2x) • 2” HEPA Filter F074 (2x) • 8” Carbon Filter AG097 (2x) |
• MERV 6-8 • MERV 10 • MERV 17 • N/A |
1-0036-4711 (6 ft of 4″ HD hose/Dual 4″ inlets) |
Dual Brushless | 54″ WC | 440 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 (2x) • 2″ Pleated Dust Filter F071 (2x) • 2” HEPA Filter F074 (2x) • 8” Carbon Filter AG097 (2x) |
• MERV 6-8 • MERV 10 • MERV 17 • N/A |
1-0036-4702 (6 ft of 3″ HD hose/Dual 3″ inlets) |
Dual Brushless | 54″ WC | 440 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 • 12″ Carbon Filter AG098 |
• MERV 6-8 • N/A |
1-0036-4712 (6 ft of 4″ HD hose/Dual 4″ inlets) |
Dual Brushless | 54″ WC | 440 | 230/1/50-60 | 12 | 150 lbs (68 kg) |
16″ | 30″ | 25.5″ | 54dB(A) | • Knockout Pad F166 • 12″ Carbon Filter AG098 |
• MERV 6-8 • N/A |
Learn how to get the most out of your Quatro Air unit and troubleshoot common problems. You can also download the owner’s manual for this unit for technical details and instructions.
Congratulations! You are now owner of a Quatro Air SPH 800 Fume Extractor, an advanced effective indoor dust and fume collection system
designed specifically to remove particulate matter and odour causing gas phase contaminants at the source. You can expect
a noticeable improvement in air quality as the SPH 800 system begins the process of reducing microscopic airborne
particulate.
Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which filters are installed &
replaced. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong
adapters to defeat proper grounding. If servicing the unit, be careful not to touch the motor as soon as it has been turned off. It is hot and can cause injury.
IMPORTANT: Ensure power supply is unplugged during maintenance or filter service
WARNING: Do not operate unit until you’ve confirmed all filters have been installed
Your unit comes equipped with a Service Filters light on the control panel. When this light is illuminated, it is recommened that you order new filters as soon as possible.
Reduced air flow is a common symptom of dirty filters.
There are a couple of reasons why your motor may randomly turn off:
No data available.
Related Products
Compact and portable, the SPH 400 Portable Fume Extractor series is designed for heavy duty laser applications.
Eliminate heavy odors and fumes generated by laser applications with the CSA 600 Fume Extractor series.
Please provide the information requested below so we can provide you with a timely and customized solution for your specific needs.