FRED Overspray Master

A professional grade, portable paint fume extractor, the FRED Overspray Master captures and filters overspray from touch up painting in automotive, aerospace, and industrial applications. The compact and portable design allows paint work to be done safely where needed, saving time and money associated with traditional fume extraction system setup costs.

Recommended Applications

  • Ideal for painting.
  • Ideal for VOC.
  • Not Ideal for deburring.
  • Not Ideal for welding.
  • Not ideal for sanding
  • Not ideal for grinding

Overview

A professional grade, portable paint fume extractor, the FRED Overspray Master captures and filters overspray from touch up painting in automotive, aerospace, and industrial applications. The compact and portable design allows paint work to be done safely where needed, saving time and money associated with traditional fume extraction system setup costs.

The Overspray Master’s 10’ XA2 Series capture arm, with external pantograph style articulation, ensures ultra-smooth repositioning while protecting components from wear and tear. Experience the ideal balance between flexibility and robust design for superior longevity, even after repeated use in industrial environments.

The portable fume extraction system includes a hood mounted paint pocket arrestor prefilter, four MERV 11 primary filters and 2 extruded carbon afterfilters for VOC fumes. Filters comply with the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 standard for toxic chromate coatings and primers, commonly found in aerospace painting applications.

Benefits

The FRED Overspray portable fume extraction system offers these key benefits in painting applications:

  • Compliant with NESHAP 319
  • Capture-at-source for cleaner air
  • Compact, portable, and easy to operate

Features

Purpose-built for painting, this configuration is tailored for highly effective VOC filtration with the following features:

  • Flexible 10’ externally articulated capture arm
  • 1200 CFM of Airflow • 1.5 HP, 120v/1/60hz blower
  • 1 x Paint pocket filter on hood • 4 x MERV 11 pleated panel filters
  • 2 x 24”x 24”x2” carbon afterfilter • 15” power cord & casters

Options

For added flexibility, FRED Overspray is available with the following options:

  • Explosion proof motor and starter
  • Choice of 6.5’, 10’ or 13’ capture arm
  • Dual-arm configurations

Models and Options

Technical Specifications

Model Motor (H.P.) Air Flow (CFM) Input Power Net Weight (lbs.) Primary
Filter
Type
After
Filter
Type
Phase Volts Hz Amps
FRED-OM-06015P1 1.5 HP 1200 1 120 60 13.2 471 Merv 11 (4) Carbon (2)
FRED-OM-015P1 1.5 HP 1200 1 120 60 13.2 471 Merv 11 (4) Carbon (2)
FRED-OM-13-015P1 1.5 HP 1200 1 120 60 13.2 471 Merv 11 (4) Carbon (2)

Dimensions

Model Arm
Length
(ft.)
Arm
Diameter
(in.)
Arm
Weight
(lbs.)
Cabinet
Weight
(lbs.)
Total
Weight
(lbs.)
Product Dimensions (in.)
Width1 Height1 Length1
FOM 10 6 55 416 471 32 98 44
FOM 13 6 55 416 471 32 98 44

1 – Product weight and dimensions are based on base-models and may vary depending on selected product features. Please contact us for an accurate shipping quote.

Learn how to get the most out of your FRED Overspray Master and troubleshoot common problems.
See our help topics and support videos below, and download the FRED Overspray Master product guide and owner’s manual.

How to..

+ Set up your FRED Overspray Master for the first time

 

Unpack Unit

  1. Inspect carton for any possible damage during transit.
  2. Use forklifts to move.
  3. Remove packing material.
  4. Do not tip or invert while handling.
  5. You’ll find the item serial number, model and electrical ratings located on the nameplate. Write down information on the provided Maintenance Record found in the owner’s manual.

Location Selection

  1. Designate a location for the unit near the operator that is sufficiently close to a grounded power source.

Installation

  1. Each machine is wired for correct rotation:
    • If motor is serviced, restart the unit.
    • Confirm motor is turning in the correct direction. (See indication arrow marked on motor).
+ Perform Function Test

Before you use your unit, you’ll want to perform a function test to verify it’s in working order.

  1. Confirm correct Voltage and Amperes
  2. Check that the Carbon Filter is properly installed.
  3. Turn the power switch to “On” for a few seconds and check that the motor rotation is correct.
  4. Look to confirm that the unit is level and stable. Verify nothing is obstructing extraction path.
  5. Start the unit.
  6. Listen closely to the motor and suction sound of the unit. Are they within the expected noise limits?
  7. Place hand on top of the unit and feel for any unexpected vibration. Place your hand in front of the intake surface to confirm the expected levels of suction.
+ Perform Routine Maintenance

 

Daily Inspection

  1. Inspect all equipment surfaces for dust buildup:
    • Wipe down as needed.
  2. Inspect carbon filters for signs of dust buildup:
    • Service as needed.
  3. Check that the gasket between the housing and the carbon canister is not damaged.
  4. Turn unit on and adjust the capture arm distance to the source so as to capture the maximum amount of fumes.

Filter Replacement- As required

  1. Replace after-filter media when it appears torn or dirty.
  2. Replace Carbon canisters after air sampling or every 6 months depending on usage and concentration of fumes being collected.

Yearly Inspection

  1. Clean labels and exterior surfaces.
  2. Check for tears in flex hoses and fitting of hose clamps.
  3. Wash cabinet internal assemblies with warm water mixed with mild detergent (Allow 12 hours to dry before use).
  4. Inspect controls for loose wiring.
  5. Examine motors for signs of unusual wear.

Troubleshooting

+ The motor does not operate on your FRED Overspray Master unit
  1. Check input power.
  2. If the problem continues, contact Diversitech support for assistance.
+ Low or restricted airflow
  1. Check motor rotation. It is possible that the unit is in reverse phasing. An electrician is required to reposition phase lines.
  2. Check filter load. Replace if necessary.
  3. If the problem continues, contact Diversitech support for assistance.
+ The motor on unit operates intermittently
  1. Perform routine maintenance on unit.
  2. If the problem continues, contact Diversitech support for assistance.

Guides

No data available.

Related Products

Request A Quote

Please provide the information requested below so we can provide you with a timely and customized solution for your specific needs.