XA4 Articulated Capture Arm

The XA4 Articulated Capture Arm comes equipped with all new features for added functionality. The XA4 empowers operators with more ways to configure their station than before using a strut-supported base and spring-assisted hanging arm.

Recommended Applications

  • Ideal for welding.
  • Not Ideal for grinding.
  • Not Ideal for deburring.
  • Not Ideal for soldering.
  • Not ideal for sanding
  • Not ideal for painting

Overview

The XA4 Articulated Capture Arm comes equipped with all new features for added functionality. The XA4 empowers operators with more ways to configure their station than before using a strut-supported base and spring-assisted hanging arm. With 360 degrees of rotation around the base, spark resistant joints throughout, and dual pivots at the hood, it’s never been easier to position your fume extraction arm for optimal capture of airborne contaminants at the source. A robust, powder-coated steel construction facilities long life and sustained performance of this capture arm in any industrial environment. Airflow control can be fine tuned thanks to the extraction arm’s internal damper. Available in 6” and 8” diameter configurations, XA4 can be customized for nearly any application with additional features including electrical grounding, LED lighting, hood mounted arrestors, and more.

Benefits

Features

  • Smooth, low-friction movement
  • Flanged suction hood
  • Wall mounted, column mounted or portable
  • Externally articulated, gas spring loaded
  • Industrial swivel-base

Options

  • Blowers (1200 to 2500 CFM)
  • Hood mounted LED light kit
  • Wall mounting bracket
  • Extension booms (5’ or 10’)

Models and Options

Technical Specifications

Blower
Model
Motor
(H.P.)
Power Air Flow
(CFM)
Cord Length
(ft.)
Type
Phase
(hz)
@120V
(amps)
@230V
(amps)
@460V
(amps)
@575V
(amps)
BR-015 1.5 1/60Hz 14.2 1200 15 TEFC
BR-030 3.0 3/60Hz 8.0 4.0 3.1 1800 N/A TEFC
BR-050 5.0 3/60Hz 12.0 6.0 4.6 2500 N/A TEFC

Arms Dimensions**

Model Item No. Type Arm
Diameter
(in.)
Arm
Length
(feet)
Net Weight (lbs.)
XA4-6H10 10019649 Hanging 6 10 59
XA4-6H13 10019650 Hanging 6 13 69
XA4-6S10 10019651 Standing 6 10 59
XA4-6S13 10019652 Standing 6 13 69
XA4-8H10 10019273 Hanging 8 10 77
XA4-8H13 10019274 Hanging 8 13 99
XA4-8S10 10019275 Standing 8 10 77
XA4-8S13 10019276 Standing 8 13 99

1 – Product dimensions are based on base-models and may vary depending on selected product features. Please contact us for an accurate shipping quote.

Learn how to get the most out of your XA4 Series Fume Extractor and troubleshoot common problems.
See our help topics and support videos below, and download the XA4 Series Articulated Capture Arm product guide and owner’s manual.

How to..

+ Set up your XA4 Series Articulated Capture Arm for the first time

Unpack Unit

  1. Inspect carton for any possible damage during transit and remove packing material.
  2. Remove packing material.
  3. Do not tip or invert while handling.
  4. You’ll find the item serial number, model and electrical ratings located on the nameplate. Write down information on the provided Maintenance Record found in the owner’s manual.

Installation

  1. Tools required:
    • 7/16 Socket or Wrench
    • 9/16 Socket or Wrench
    • Torque Wrench

Arm to Remote Mount Bracket Installation

  1. Unpack capture arm, hood, and base
  2. Wall mount bracket standard assembly:
    • Mount Swivel Base to Remote Mount Bracket.
    • Tighten all Bolts (8) with Washers (8).
    • Torque each bolt to 23 N m.
  3. Attach swivel base to remote mount bracket.
  4. Attach capture arm to swivel base:
    • Mount Swivel Base to Remote Mount Bracket.
    • Tighten all Bolts (8) with Washers (8).
    • Torque each bolt to 23 N m.
+ Perform Routine Maintenance

Yearly Inspection:

  1. Clean unreadable labels and exterior surfaces.
  2. Check for tears in flex hoses and fitting of hose clamp.

Troubleshooting

+ The suction arm is not able to support itself, the handling and positioning of the hood is compromised
  1. Check bolts to see if they’re loose. If so, tighten bolts gradually. Be careful not to overtighten.
+ The pipes break in the proximity of the junction
  1. The bolts of the clutches are tightened too much, to the point of overcoming the resistance of the junctions. Loosen the bolts of the clutches and replace the pipes:
    • The forearm tube of connection hood. (Replacement can be done by customer.)
    • The part of the pipe where there’s a spring. (Replacement must be done by manufacturer for safety reasons.)
+ Broken hose clamps
  1. There was wear, drilling and/ or abrasion caused by incandescent material extracted by the arm. Remove and replace hose clamps.
+ The fan’s suction arm stops suddenly
  1. There may be a block of electric current. Reactivate the power source of the current.
  2. Check the fuse to see if it’s blown. Replace if necessary.
  3. Check the thermal switch to see if it has tripped. Open the control panel and reset the switch. Investigate the reason for the thermal cutoff.
  4. The engine may have blown. Repair or replace if possible. Refer to appropriate manual.